Welcome to VTE Europe your home for high quality Terminal Insulators and Electro-Mechanical components. As a proud manufacturer for over 40 years, we have the experience and the know how to meet the requirements for your project.

Three very simple, yet extremely important reasons why you should integrate the VTE range of Terminal Insulators into your products:

- Industry standards state that each non grounded terminal or stud that is continuously energised must have a boot, cap, cover or shield that prevents accidental short-circuiting at the terminals or studs.
- Our Terminal Insulators are a safe and cost effective way to adhere to these standards.
- With our products being designed and manufactured to the highest standards, satisfaction is guaranteed.

We received ISO 9001:2015 Certification from the American Center for Sustainable Certifications on Nov 6, 2024.

With over 2,000 product lines available as a factory option, there is bound to be a product suitable for your application.

### Code Features Available

- N — Normal  
- E — Extended Length (200 Series Only)  
- L — Left Handed Cable Entries Only  
- R — Right Handed Cable Entries Only  
- D — Dual Cable Entries Only  

### ORDERING GUIDE

**SAMPLE 8 DIGIT PART NUMBER**  
`234N4V02`  
- Series Number  
- Features  
- Material  
- Colour  

**ORDERING GUIDE (SAMPLE FORMAT)**  
`2 3 4 N 4 V 0 2`  
Series — Number — Code — Colour — Material — Cable Entry  

### Code Materials Available

- V — Vinyl - (Standard, Self Extinguishing)  
- F — Vinyl - (Fire Retardant Material, Non Flammable)  
- E — TPV - (Thermoplastic Vulcanizate)*  
- R — TPR - (Trexprene Thermoplastic Rubber)  
- T — TPR - (Sentoprene Thermoplastic Rubber)  

\* High chemical and UV resistance

### Materials Properties

| Code | U.L. 94 Flame Class | Brittleness Temp °C | Service Temp °C | Tensile Strenth PSI | Elongation % | Tear Strength PPI |
|---|---|---:|---:|---:|---:|---:|
| V | V-2 | -48 | 105 | 1550 | 230 | 230 |
| F | V-0 | -30 | 105 | 1500 | 350 | 230 |
| E | HB | -60 | 180 | 972 | 139 | 131 |
| R | ? | -60 | ? | 475 | ? | 239 |
| T | HB | <-60 | 125 | 1020 | 131 | 131 |

### Code Colours Available

- 00 — Clear  
- 02 — Red  
- 04 — Orange  
- 05 — Yellow  
- 07 — Dark Green  
- 09 — Blue  
- 13 — Grey  
- 14 — Black  

CAGE Code -  
Defence Compliant  

## INTRODUCTION

OUR PVC’S ARE UL LISTED: V0 & V02. MOST OF OUR MATERIALS ARE ROHS & REACH COMPLIANT  

J2120 (2009 EDITION)  
Underwriters Laboratories  

---

## 02

### 200 Series - Finding the correct insulator

- 212 Series to 234 Series  
- 200 Series Terminal Insulators  
- 200 Series Terminal Insulators  
- Gauging Template for 690 & 960 Series  
- Sizing Chart for 690 & 960 Series  
- 258 Series to 488 Series  
- 490 Series to 960 Series  
- Lug & Ring Terminal Insulators  

| Item | Page |
|---|---:|
| Page 03 | 03 |
| Page 04 | 04 |
| Page 05 | 05 |
| Page 06 | 06 |
| Page 07 | 07 |
| Page 08 | 08 |
| Lug & Ring Terminal Insulators | 06 |
| 490 Series to 960 Series | 08 |

409 Series to 458 Series — Page 09  
500 Series to 468 Series — Page 10  
730 Series to 976 Series — Page 11  

Battery Terminal Insulators — Page 09–11  

433 Series to 799 Series — Page 12  
L-Post Terminal Insulators  

310 Series to 479 Series — Page 13–14  
Specialty Terminal Insulators  

419 Series to 457 Series — Page 16  
451 Series to 484 Series — Page 17  
Adapter Terminal Insulators  

### Introduction to Electro-Mechanical

- Page 18  
- Power Posts — Page 19–21  
- Power Bushings & Terminal Busbars — Page 22–25  
- Fuse Holders — Page 26  

Metric Range  
- Page 27–30  
Imperial Range  
- Page 31–35  
- Page 36–38  

ELECTRO-MECHANICAL  

---

## 03

### TERMINAL INSULATORS

For use with stud-type terminal posts

- N = Standard Terminal Length  
- E = Extra Terminal Length  

#### Cable Entry
1. **Cable Entry 1**  
   - 5.84mm  
   - 3.30mm  
   - Cable Gauges 18 - 10  
   - 0.8mm² [3.24mm] to 5mm² [5.42mm]  

2. **Cable Entry 2**  
   - 12.7mm  
   - 7.62mm  
   - Cable Gauges 8 - 2  
   - 8mm² [6.98mm] to 32mm² [11.93mm]  

3. **Cable Entry 3**  
   - 17.78mm  
   - 12.70mm  
   - Cable Gauges 2 - 2/0  
   - 32mm² [11.93mm] to 62mm² [16.0mm]  

4. **Cable Entry 4**  
   - 22.86mm  
   - 17.78mm  
   - Cable Gauges 3/0 - 4/0  
   - 81mm² [18.3mm] to 103mm² [19.8mm]  

#### FINDING THE CORRECT INSULATOR

1. Determine your terminal’s outside diameter (A)  
2. Determine your terminal’s post height (B)  
3. Determine your terminal’s cable entry (D)  

Match your terminal’s measurements against the dimensions table to find the correct insulator for your application.

* Images are for illustration purposes only.

#### Dimensions Table — 200 Series (Metric Range)

| Base Part Number | A Terminal O.D. (mm) | B Post Height (mm) | C Ins. Grip Diameter (mm) | D Cable Entry Options | E Terminal Length (mm) | Nominal Material Thickness (mm) |
|---|---:|---:|---:|---|---:|---:|
| 212N | 12 | 17.8 | 12.7 | 1, 2 | 25.4 | 1.5 |
| 212E | 12 | 17.8 | 12.7 | 1, 2 | 31.8 | 1.5 |
| 214N | 14 | 19.1 | 12.7 | 1, 2 | 25.4 | 1.5 |
| 214E | 14 | 19.1 | 12.7 | 1, 2 | 31.8 | 1.5 |
| 216N | 16 | 20.3 | 12.7 | 1, 2 | 25.4 | 1.5 |
| 216E | 16 | 20.3 | 12.7 | 1, 2 | 31.8 | 1.5 |
| 218N | 18 | 22.1 | 12.7 | 1, 2 | 25.4 | 1.5 |
| 218E | 18 | 22.1 | 12.7 | 1, 2 | 31.8 | 1.5 |
| 220N | 20 | 24.1 | 17.8 | 1, 2, 3 | 33.5 | 1.8 |
| 220E | 20 | 24.1 | 17.8 | 1, 2, 3 | 44.5 | 1.8 |
| 222N | 22 | 26.7 | 17.8 | 1, 2, 3 | 41.2 | 2.0 |
| 222E | 22 | 26.7 | 17.8 | 1, 2, 3 | 52.3 | 2.0 |
| 224N | 24 | 28.7 | 17.8 | 1, 2, 3 | 41.2 | 2.0 |
| 224E | 24 | 28.7 | 17.8 | 1, 2, 3 | 52.3 | 2.0 |
| 226N | 26 | 31.8 | 19.1 | 1, 2, 3 | 44.5 | 2.3 |
| 226E | 26 | 31.8 | 19.1 | 1, 2, 3 | 57.2 | 2.3 |
| 228N | 28 | 33.5 | 19.1 | 1, 2, 3 | 44.5 | 2.5 |
| 228E | 28 | 33.5 | 19.1 | 1, 2, 3 | 57.2 | 2.5 |
| 230N | 30 | 35.6 | 22.9 | 1, 2, 3, 4 | 44.5 | 2.5 |
| 230E | 30 | 35.6 | 22.9 | 1, 2, 3, 4 | 60.5 | 2.5 |
| 232N | 32 | 38.1 | 22.9 | 1, 2, 3, 4 | 50.8 | 2.5 |
| 232E | 32 | 38.1 | 22.9 | 1, 2, 3, 4 | 66.8 | 2.5 |
| 234N | 34 | 40.6 | 22.9 | 1, 2, 3, 4 | 50.8 | 2.5 |
| 234E | 34 | 40.6 | 22.9 | 1, 2, 3, 4 | 66.8 | 2.5 |

www.vte.nl I 200 Series Terminal Insulators  
FINDING THE CORRECT INSULATOR  
03  
200 SERIES DIMENSIONS TABLE  
METRIC RANGE TERMINAL BUSBARS FUSE HOLDERS POWER POSTS POWER BUSHINGS  

---

## 04

www.vte.nl I 200 Series Terminal Insulators

Our Terminal Insulators protect live power connections from accidental shorts. Several standards require that continuously charged connections must be protected from accidental shorts, which our product range fulfils.

Our insulators are available in multiple colours, materials and sizes.#  

The 200 Series Terminal Insulators are designed to protect ring and lug terminals.  
They are available in sizes from 12mm up to 34mm diameter and are manufactured from PVC, which has a 105°C temperature rating.

Optional features include extended length for longer terminals and can be manufactured in 5 colours.

While the 200 Series line is commonly used on inverters, starters, windlasses, chargers and other high energy connections, it also works for many applications and helps your products comply with industry safety standards.

The 200 Series Terminal Insulators work with stud and eyelet terminals.

This Series can be ordered with an extended (E) length for longer terminals.

### Terminal Outer Diameter — Series

| Terminal Outer Diameter | 212 Series | 214 Series | 216 Series | 218 Series | 220 Series | 222 Series | 224 Series | 226 Series | 228 Series | 230 Series | 232 Series | 234 Series | * Cable Gauge Range |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Terminal O.D.* | 12mm | 14mm | 16mm | 18mm | 20mm | 22mm | 24mm | 26mm | 28mm | 30mm | 32mm | 34mm | 18 - 2 gauge / 18 - 2/0 gauge / 18 - 4/0 gauge |

**200 SERIES TERMINAL INSULATORS**  
04  

# MoQ’s May Apply  
TERMINAL INSULATORS POWER BUSHINGS POWER POSTS FUSE HOLDERS TERMINAL BUSBARS METRIC RANGE  

---

## 05

Insulators for Right Angle (90 Degree) Terminals

Fits 8ga (8mm²) up to 4/0 (103mm²) terminals/cables

Available in 2 Materials:  
- V Material (UL-V2)  
- F Material (UL-V0)  

Protect right angle terminals in confined spaces

TERMINAL INSULATORS  
05  

LUG & RING  

GAUGING TEMPLATE FOR 690 & 960 SERIES  

www.vte.nl I Lug & Ring Terminal Insulators  

TERMINAL INSULATORS POWER BUSHINGS POWER POSTS FUSE HOLDERS TERMINAL BUSBARS METRIC RANGE  

---

## 06

690 Series

| Part Number | Cable Opening | Terminal Width | Terminal Length | Rated Size | Colour |
|---|---:|---:|---:|---|---|
| 691N9V02 | 7.87mm | 19.69mm | 28.7mm | 8 - 19mm² | Red |
| 691N9V14 | 7.87mm | 19.69mm | 28.7mm | 8 - 19mm² | Black |
| 692N9V02 | 12.34mm | 19.56mm | 27.38mm | 32 - 40mm² | Red |
| 692N9V14 | 12.34mm | 19.56mm | 27.38mm | 32 - 40mm² | Black |
| 693N9V02 | 13.72mm | 20.83mm | 28.83mm | 50mm² | Red |
| 693N9V14 | 13.72mm | 20.83mm | 28.83mm | 50mm² | Black |
| 694N9V02 | 14.73mm | 21.34mm | 30.23mm | 60mm² | Red |
| 694N9V14 | 14.73mm | 21.34mm | 30.23mm | 60mm² | Black |
| 695N9V02 | 16.41mm | 23.37mm | 30.23mm | 81mm² | Red |
| 695N9V14 | 16.41mm | 23.37mm | 30.99mm | 81mm² | Black |
| 696N9V02 | 17.78mm | 25.91mm | 31.95mm | 103mm² | Red |
| 696N9V14 | 17.78mm | 25.91mm | 31.95mm | 103mm² | Black |

960 Series

| Part Number | Cable Opening | Terminal Width | Terminal Length | Rated Size | Colour |
|---|---:|---:|---:|---|---|
| 962N9V02 | 10.67mm | 19.43mm | 29.97mm | 13mm² | Red |
| 962N9V14 | 10.67mm | 19.43mm | 29.97mm | 13mm² | Black |
| 963N9V02 | 11.94mm | 19.05mm | 29.97mm | 19mm² | Red |
| 963N9V14 | 11.94mm | 19.05mm | 29.97mm | 19mm² | Black |
| 964N9V02 | 16.92mm | 22.91mm | 38.18mm | 32 - 40mm² | Red |
| 964N9V14 | 16.92mm | 22.91mm | 38.18mm | 32 - 40mm² | Black |
| 965N9V02 | 18.34mm | 24.51mm | 37.8mm | 50mm² | Red |
| 965N9V14 | 18.34mm | 24.51mm | 37.8mm | 50mm² | Black |
| 966N9V02 | 17.93mm | 27.53mm | 38.18mm | 60mm² | Red |
| 966N9V14 | 17.93mm | 27.53mm | 38.18mm | 60mm² | Black |
| 967N9V02 | 22.17mm | 29.97mm | 38.23mm | 81mm² | Red |
| 967N9V14 | 22.17mm | 29.97mm | 38.23mm | 81mm² | Black |
| 968N9V02 | 22.17mm | 34.62mm | 40.51mm | 103mm² | Red |
| 968N9V14 | 22.17mm | 34.62mm | 40.51mm | 103mm² | Black |

MEDIUM DUTY LUG & RING TERMINAL INSULATORS  
691N9V02 692N9V02 693N9V02 694N9V02 695N9V02 696N9V02  
962N9V02 963N9V02 964N9V02 965N9V02 966N9V02 967N9V02  

HEAVY DUTY LUG & RING TERMINAL INSULATORS  
LUG & RING  

TERMINAL INSULATORS  
LUG & RING  

---

## 07

www.vte.nl I Lug & Ring Terminal Insulators

A more comprehensive line of Insulators offering a wider variety of Lug and Ring protection. Our Lug & Ring Insulators can be used with starters, generators, alternators, solenoids and other devices. These insulators are available in different sizes, shapes , materials and colours, providing specific solutions to your exact needs.

The 258 Series protects large terminal connections.  
- Terminal Outside Diameter: 58.7mm [2.3"]  
- Max Post Height: 50.8mm [2.0"]  
- Accepts multiple cables, up to 1/0 ga each.

258 Series Part No. Cable Entry Size  
- 258N4 — Round, 3/0 - 4/0  
- 258N9 — Oval, up to 4/0  

The 216T Series is a snap-on insulator and can be removed without cable.  
- Terminal Outside Diameter: 16.3mm [0.64"]  
- Maximum Post Height: 18.8mm [0.74"]

216T Series Part No. Cable Entry Size  
- 216T8 — 6.9mm [.27"]  

The 400 Series is designed to cover a post, eyelet or ring terminal.  
- Terminal Outside Diameter: 15.2mm [0.6"]  
- Maximum Post Height: 22.4mm [0.88"]

400 Series Part No. Cable Entry Size  
- 400N7 — 7.9mm [.31"]  
- 400N9 — 11.2mm [.44"]  
- 400E4 — 4.6mm [.18"]  

The 405 & 406 Series have a low profile and flattened cap, designed to work in tight fitting areas.  
- Terminal Outside Diameter: 25.4mm [1.0"]  
- Maximum Post Height: 24.8mm [0.98"]

405 / 406 Series Part No. Cable Entry Size  
- 405N1 — 3.3mm [.13"]  
- 405N2 — 7.6mm [.30"]  
- 405N9 — 12.7mm [.50"]  
- 406N3 — 4.1mm [.16"]  
- 406N9 — 19.0mm [.75"]  

The 407 Series is designed to work with a single eyelet, ring terminal and post.  
- Terminal Outside Diameter: 17.53mm [0.69"]  
- Maximum Post Height: 25.8mm [1.01"]

407 Series Part No. Cable Entry Size  
- 407N6 — 12.7mm [.50"]  
- 407N8 — 15.7mm [.62"]  

The 470 Series is designed to work with a single eyelet, ring terminal and post.  
- Terminal Outside Diameter: 21.6mm [0.85"]  
- Maximum Post Height: 26.9mm [1.06"]

470 Series Part No. Cable Entry Size  
- 470N9 — 15.9mm [.63"]  

The 485 Series is designed to cover a post and single eyelet or ring terminal.  
- Terminal Outside Diameter: 12.9mm [0.52"]  
- Maximum Post Height: 11.4mm [0.45"]

485 Series Part No. Cable Entry Size  
- 485N9 — 6.4mm [.25"]  

The 487 & 488 Series are designed to cover a post and single eyelet or ring terminal.  
- Terminal Outside Diameter: 32mm [1.26"]  
- Maximum Post Height: 24.9mm [0.98"]

487 / 488 Series Part No. Cable Entry Size  
- 487N6 — 12.7mm [.5"]  
- 487N7 — 15.2mm [.6"]  
- 487N8 — 16.5mm [.65"]  
- 487N9 — 19.0mm [.75"]  
- 488N9 — 22.1mm [.87"]  

TERMINAL INSULATORS LUG & RING  
07 www.vte.nl I Lug & Ring Terminal Insulators  

TERMINAL INSULATORS METRIC RANGE TERMINAL BUSBARS FUSE HOLDERS POWER POSTS POWER BUSHINGS  

---

## 08

The 490 Series is designed for use with angled terminal connections.  
- Terminal Outside Diameter: 19.1mm [0.75"]  
- Maximum Post Height: 27.2mm [1.07"]

490 Series Part No. Cable Entry Size  
- 490N9 — 12.7mm [.5"]  

The 510 Series is useful for protecting solenoid type connections.  
- Terminal Outside Diameter: 12.7mm [0.5"]  
- Maximum Post Height: 20.3mm [0.8"]

510 Series Part No. Cable Entry Size  
- 510N9 — 6.4mm [.25"]  

The 600 Series features a large insulator cap allowing for several connections.  
Available in 7 different cable entries and accepts up to 4/0 awg cables.

- Terminal Outside Diameter: 40mm [1.57"]  
- Maximum Post Height: 41.1mm [1.62"]

600 Series Part No. Cable Entry Size  
- 600N1 — (1) 7.9mm [.31"]  
- 600N2 — (2) 7.9mm [.31"]  
- 600N3 — (1) 12.7mm [.5"]  
- 600N4 — (2) 12.7mm [.5"]  
- 600N5 — (1) 15.8mm [.62"]  
- 600N6 — (2) 15.8mm [.62"]  
- 600N7 — Oval up to 4/0 ga  

The 620 Series is designed with a finger pull tab on cap for easy removal.  
- Terminal Outside Diameter: 19.1mm [0.75"]  
- Maximum Post Height: 16.8mm [0.66"]

620 Series Part No. Cable Entry Size  
- 620N4 — 3.3mm [.13"]  

The 690 Series is suited for medium duty right angle terminals and protects terminals located in confined spaces.  
Accepts 8ga to 4/0ga terminals (8 - 103mm²)

690 Series Cable Entry  
- 691N9 — Cable entry sizes: 3.9mm, etc.  
- 692N9  
- 693N9  
- 694N9  
- 695N9  
- 696N9  

The 800 Series is specifically designed with a retaining ring inside the cap which holds the terminal base.  
- Terminal Outside Diameter: 18.5mm [0.73"]  
- Maximum Post Height: 26.2mm [1.03"]

800 Series Part No. Cable Entry Size  
- 800N3 — 4.3mm [.17"]  
- 800N4 — 4.3mm [.17"]  
- 800N5 — 5.3mm [.21"]  
- 800N8 — 7.9mm [.31"]  
- 800N9 — 12.7mm [.50"]  

The 801 Series is suited for single sized cable with an eyelet or ring terminal.  
- Terminal Outside Diameter: 19.1mm [0.75"]  
- Maximum Post Height: 26.2mm [1.03"]

801 Series Part No. Cable Entry Size  
- 801N8 — 7.9mm [.31"]  

The 960 Series is designed for use with heavy duty right angle terminals and protects terminals in confined spaces.  
Accepts 8ga to 4/0ga terminals (8 - 103mm²)

960 Series Cable Entry  
- 962N9  
- 963N9  
- 964N9  
- 965N9  
- 966N9  
- 967N9  
- 968N9  

Refer to gauging template & sizing chart on pages 5 & 6  

08  
TERMINAL INSULATORS LUG & RING  
www.vte.nl I Lug & Ring Terminal Insulators  

---

## 09

www.vte.nl I Battery Terminal Insulators

We manufacture a complete line of Battery Terminal Insulators. These Insulators are designed for use in marine, commercial, industrial and automotive fields.

Our Battery Terminal Insulators offer solutions in single and multiple cables and are available in various materials, sizes and colours #.

### 409 Series
Designed to protect stamped wrap battery terminals.  
- Maximum Post Height: 21.0mm [0.83"]  
- Cable Entry: 8 ga - 1/0 ga  

409 Series Part No. Cable Entry Size  
- 409N2 — 7.2mm [.29"]  
- 409N3 — 12.7mm [.50"]  
- 409N9 — 7.6mm [.30"]  

### 415 Series
Suited to protect tapered style battery terminals.  
- Maximum Post Height: 18.8mm [0.74"]  
- Cable Entry: 1/0 ga - 2/0 ga  

415 Series Part No. Cable Entry Size  
- 415N6 — 9.4mm [.37"]  
- 415N7 — 11.2mm [.44"]  
- 415N8 — 12.7mm [.50"]  
- 415N9 — 15.9mm [.62"]  
- 415N0 — 19.1mm [.75"]  

### 416 Series
Popular solution for battery terminal installation.  
- Maximum Post Height: 19.3mm [0.76"]  
- Cable Entry: 16.mm [0.63"]  

416 Series Part No. Cable Entry Size  
- 416N9 — 16.0mm [.63"]  

### 417 Series
Snap on insulator which can be removed without cable.  
- Maximum Post Height: 23.1mm [0.91"]  
- Cable Entry: 1 - 1/0 ga  

417 Series Part No. Cable Entry Size  
- 417N9 — 12.7mm [.50"]  

### 430 Series
Designed to protect tapered style battery posts.  
- Maximum Post Height: 21.1mm [0.83"]  
- Cable Entry: 2/0, 3/0 ga  

430 Series Part No. Cable Entry Size  
- 430N7 — 14.2mm [.56"]  
- 430N8 — 17.3mm [.68"]  

### 455 Series
Suited to protect a dual post battery, the insulator snaps easily onto the cable and can be fastened with a zip-tie.  
Accepts multiple cables of different sizes.

455 Series Part No. Cable Entry Size  
- 455N4 — 10.0mm [.4"]  
- 455N6 — 12.7mm [.5"]  
- 455N8 — 19.1mm [.75"]  

### 458 Series
Designed for a dual post battery and the attached cover can insulate the post when not in use.  
Often used with 226 Series Insulator.

458 Series Part No. Cable Entry Size  
- 458N0 — N/A  

# MoQ’s May Apply  

TERMINAL INSULATORS BATTERY  
09 www.vte.nl I Battery Terminal Insulators  

TERMINAL INSULATORS METRIC RANGE TERMINAL BUSBARS FUSE HOLDERS POWER POSTS POWER BUSHINGS  

---

## 10

The 500 Series is the popular choice for battery terminal protection.  
Available in left, right and dual entry cable options.

- Cable Entry: Up to 12.7mm [0.5"]

500 Series

### 553 Series
Designed to protect side post battery terminal connections.  
Featuring a retaining loop that keeps the insulator with the battery or cable.  
Available with 2 cable entries.

553 Series Part No. Cable Entry Size  
- 553X6 — 15.0mm [.59"]  
- 553X9 — 22.9mm [.90"]  

### 460 Series
Dual post battery insulator specifically fits the Exide Group 32 marine battery.  
Featuring a tabbed finger grip for easy removal and allows for a secondary battery connection.

460 Series Part No. Cable Entry Size  
- 500L7 — 12.7mm [.50"]  
- 500L9 — 17.5mm [.69"]  
- 500R7 — 12.7mm [.50"]  
- 500R9 — 17.5mm [.69"]  
- 500D7 — 12.7mm [.50"]  
- 500D9 — 17.5mm [.69"]  
- 500B — N/A  

### 462 & 463 Series
Designed to protect dual post battery terminals used in the marine industry.  
Terminal connection centre to centre: 43.69mm  
The attached caps cover the post when not in use.

462 / 463 Series Part No. Entry Size  
- 462N0 — N/A  
- 463N0 — N/A  

### 466 Series
Designed to protect large heavy duty battery terminals.  
Available in left, right and dual cable entries.

466 Series

### 468 Series
Protects large heavy duty battery terminals and has been designed to snap onto the terminal and cable allowing for easy access.  
Available in left, right and dual cable entries.

468 Series Part No. Cable Entry Size  
- 468L9 — 20.8mm [.82"]  
- 468R9 — 20.8mm [.82"]  
- 468D9 — 20.8mm [.82"]  

Part No. Cable Entry Size  
- 460N9 — N/A  
Part No. Cable Entry Size  
- 466L1, R1 — 3.3mm [.13"]  
- 466L2, R2 — 7.6mm [.30"]  
- 466L3, R3 — 12.7mm [.50"]  
- 466N9 — Oval up to 4/0 ga  

Colour  
Black  
Red  
Left Entry Right Entry Oval Entry  

TERMINAL INSULATORS BATTERY  
10 www.vte.nl I Battery Terminal Insulators  

TERMINAL INSULATORS METRIC RANGE TERMINAL BUSBARS FUSE HOLDERS POWER POSTS POWER BUSHINGS  

---

## 11

The 730 (Black) & 731 (Red) Series are suited to protect large wing nut type terminal connections.  
The top swivels to accommodate cables from various directions.  
Top insulator offers single, dual and multiple cable entries.

730 / 731 Series

### 843 Series
Designed to cover a tapered battery post.  
Available in left and right cable entry.

Maximum Post Height: 20.1mm [0.79"]

843 Series Part No. Cable Entry Size  
- 843L8 — 11.2mm [.44"]  
- 843L9 — 12.7mm [.50"]  
- 843R8 — 11.2mm [.44"]  
- 843R9 — 12.7mm [.50"]  

### 900 Series
Popular solution to cover cast-on lead terminals.  
Available in left, right and dual cable entry.  
Cable entry can be cut and zip-tied for up to 4/0 awg.

900 Series Part No. Cable Entry Size  
- 900L9 — 16.0mm [.63"]  
- 900R9 — 16.0mm [.63"]  
- 900D9 — 16.0mm [.63"]  

### 974 Series
Protects large battery terminal connections.  
Maximum Post Height: 29.9mm [1.18"]  
Cable Entry: Large -20.3 mm [0.8"] diameter

974 Series Part No. Cable Entry Size  
- 974N9 — 20.3mm [.80"]  

### 975 Series
Designed to protect large battery terminal connections.  
Features large cable entry for flag or right angle terminals.  
Cable Entry: Up to 4/0 ga

975 Series Part No. Cable Entry Size  
- 975D8 — 20.3mm [.80"]  

### 976 Series
Suited to protect large battery terminal connections; triple cable entry allows for 3 cable connections.  
Cable Entry: Up to 4/0 ga

976 Series Part No. Cable Entry Size  
- 976N8 — 20.3mm [.80"]  

Part No. Cable Entry Size  
- 730N1  
- 730N2  
- 730N3  
- 730N4  
- 730N5  
- 730N6  
- 730N7  

(1) 7.9mm [.31"]  
(2) 7.9mm [.31"]  
(1) 12.7mm [.5"]  
(2) 12.7mm [.5"]  
(1) 15.8mm [.62"]  
(2) 15.8mm [.62"]  
Oval up to 4/0 ga  

Black  
731N1  
731N2  
731N3  
731N4  
731N5  
731N6  
731N7  

Red  

TERMINAL INSULATORS BATTERY  
11 www.vte.nl I Battery Terminal Insulators  

TERMINAL INSULATORS METRIC RANGE TERMINAL BUSBARS FUSE HOLDERS POWER POSTS POWER BUSHINGS  

---

## 12

The 433 Series is a large insulator and is suited to protect large L-Post terminal connections.  
Available with left and right entry.  
Maximum Post Height: 26.4mm [1.04"]

The 436 Series is designed to protect flat threaded or low profile posts.  
The insulator snaps onto the cable and can be secured with a zip-tie.  
Maximum Post Height: 19.1mm [0.75"]  

436 Series

The 437 Series is similar to the 436 Series but suits a greater terminal height.  
The insulator snaps onto the cable and can be secured with a zip-tie.  
Maximum Post Height: 32.5mm [1.28"]

437 Series

The 439 Series has a large design allowing the fitting of various terminals.  
The insulator snaps onto the cable and can be secured with a zip-tie.  
Maximum Post Height: 32.5mm [1.28"]

439 Series Part No. Cable Entry Size  
- 439N5 — 9.6mm [.38"]  

The 444 Series protects smaller L-Post and Flag battery connections.  
Available in left or right entry cable.  
Maximum Post Height: 30.5mm [1.2"]

444 Series

The 799 Series is suited to protect L-Post and Flag battery connections.  
The insulator snaps onto the cable and can be secured with a zip-tie.  
Maximum Post Height: 38.3mm [1.51"]

799 Series Part No. Cable Entry Size  
- 799L9 — 6.4mm [.25"]  
- 799R9 — 6.4mm [.25"]  
- 799D9 — 6.4mm [.25"]  

Part No. Cable Entry Size  
- 437N4 — 9.3mm [.36"]  
- 437N5 — 11.4mm [.46"]  
- 437N7 — 12.3mm [.48"]  
- 437S5 — 10.0mm [.40"]  

Part No. Cable Entry Size  
- 444L6 — 7.6mm [.30"]  
- 444R6 — 7.6mm [.30"]  
- 444L8 — 9.4mm [.37"]  
- 444R8 — 9.4mm [.37"]  
- 444L9 — 11.2mm [.44"]  
- 444R9 — 11.2mm [.44"]  

L-Post Terminal Insulators protect Flag terminals and L-Post terminals from accidental shorts and adverse weather.  
Protect your connections, comply with industry safety standards, and improve the look of your cabling, wiring and terminal connections.

Cable Entry Size  
433L5 — 11.2mm [.44"]  
433R5 — 11.2mm [.44"]  

Part No. Cable Entry Size  
436N4 — 9.2mm [.36"]  
436N5 — 12.2mm [.48"]  
436N7 — 16.2mm [.64"]  
436S4 — 9.0mm [.35"]  
436S5 — 12.2mm [.48"]  

433 Series  
L-POSTS  

TERMINAL INSULATORS  
12  
www.vte.nl I L-Post Terminal Insulators  

TERMINAL INSULATORS METRIC RANGE TERMINAL BUSBARS FUSE HOLDERS POWER POSTS POWER BUSHINGS  

---

## 13

Protective disk for various uses in our insulators  
- Available in 2 entry hole sizes or without entry hole  

For use with 778 Series Post, 480 Series and 476 Series

Protective covers for small circuit breakers  
- Removable side entries to customise application  
- Top cover presses down onto circuit breaker posts  

Made from fire retardant PVC

Protective covers for 7753N7 - 3 Point High Amp Busbar  
Cable entry allows 2/0, up to 4/0 ga cable  
Insulator snaps onto cable  
Grommet used to seal off cable entry holes  
Protects cables from sharp edges  

Fits Hole Diameter: 25.4mm [1.0"]  
Maximum Panel Thickness: 1.5mm [0.06"]

Grommet used to seal off cable entry holes  
Protects cables from sharp edges  
Fits Hole Diameter: 25.4mm [1.0"]  
Outer Diameter: 39.1mm [1.54"]

311 Series  
Part No. Cable Entry Size  
- 310N4 — 6.4mm [.25"]  
- 310N6 — 7.1mm [.28"]  
- 310N7 — 9.7mm [.38"]  
- 310N8 — 10.2mm [.40"]  
- 310N9 — 12.7mm [.50"]  

375 Series Part No. Cable Entry Size  
- 375T5 — 15.2mm x 30.5mm  

464 Series Part No. Cable Entry Size  
- 464N0 — 6.2mm [.24"]  

479 Series Part No. Cable Entry Size  
- 479A9 — 16.0mm [.63"]  
- 479B9 — 19.6mm [.77"]  
- 479N9 — N/A  

We manufacture a large range of Specialty Insulators, to fit many unusual applications. We offer insulators for power connectors, circuit breakers, cable entry points and many other solutions. Many solutions are engineered from customer inquiries, filling any void in the industry.

310 Series  
Commonly used with our Auxiliary Power Connector  
Insulator cover has retaining ring  
Cap has retainer entry width of 30.48mm  

321 Series Part No. Cable Entry Size  
- 321N9 — 34.8mm [1.37"]  

TERMINAL INSULATORS SPECIALTY  
13 www.vte.nl I Specialty Terminal Insulators  

TERMINAL INSULATORS METRIC RANGE TERMINAL BUSBARS FUSE HOLDERS POWER POSTS POWER BUSHINGS  

---

## 14

Protects engine sensors  
Generous height and downward wire exit  
Retainer lip keeps insulator in place  
Wall Thickness: 1.0mm [0.03"]

550 Series Cable Entry Size  
- 550N6 — 6.4mm [.25"]  
- 550N9 — 9.5mm [.38"]

Protects engine sensors  
Generous height and downward wire exit  
Retainer lip keeps insulator in place  
Wall Thickness: 2.8mm [0.11"]

560 Series Cable Entry Size  
- 560N4 — 6.4mm [.25"]

Small straight sensor cover  
Moulded in ring provides greater strength  
Typically used with oil & water temperature sensors  
Material options allow the 621 to be used in high temperature environment

621 Series Cable Entry Size  
- 621N9 — 6.4mm [.25"]

725 Series  
Accepts terminals up to 24mm  
Tunnel cap allows for various cable entry sizes and shapes  
Maximum Terminal O.D: 24mm [0.94"]  
Maximum Terminal Height: 25.3mm [0.99"]

725 Series Cable Entry Size  
- 224T9 — Various Inserts

729 Series  
Accepts terminals up to 28mm  
Tunnel cap allows for various cable entry sizes and shapes  
Maximum Terminal O.D: 28mm [1.10"]  
Maximum Terminal Height: 30.7mm [1.20"]

729 Series Cable Entry Size  
- 228T9 — Various Inserts

735 Series  
Accepts terminals up to 34mm  
Tunnel cap allows for various cable entry sizes and shapes  
Maximum Terminal O.D: 34mm [1.52"]  
Maximum Terminal Height: 38.6mm [1.30"]

735 Series Cable Entry Size  
- 234T9 — Various Inserts

Style A Style B Style C  
Style A Style B Style C  
Style A Style B Style C  

Ref to Website Chart for Sizes & Functionality  
Ref to Website Chart for Sizes & Functionality  
Ref to Website Chart for Sizes & Functionality  

SPECIALTY  
14  

TERMINAL INSULATORS  
www.vte.nl I Specialty Terminal Insulators  

TERMINAL INSULATORS METRIC RANGE TERMINAL BUSBARS FUSE HOLDERS POWER POSTS POWER BUSHINGS  

---

## 15

Snap on top allows access to connection points  
Works great with the 770 and 771 Series Power Posts

Single Entry Diameter: 17.8mm [0.7"]

795 Series Part No. Cable Entry Size  
- 795 — 17.8mm [.7"]

Cover for 50 Amp Anderson or SMH 2 Pole battery  
Loop end retains insulator to cable  
Made from fire retardant PVC

830 Series Part No. Cable Entry Size  
- 830N0 — N/A

Cover for 175 Amp Anderson or SMH 2 Pole battery  
Loop end retains insulator to cable  
Made from fire retardant PVC

831 Series Part No. Cable Entry Size  
- 831N0 — N/A

Cover for 350 Amp Anderson or SMH 2 Pole battery  
Loop end retains insulator to cable  
Made from fire retardant PVC

832 Series Part No. Cable Entry Size  
- 832N0 — N/A

Small right angle sensor cover, used with oil and water temperature sensors  
Body Opening: 20.6mm [0.81"]  
Cable Entry: 6.4mm [0.25"]

840 Series Part No. Cable Entry Size  
- 840N9 — 6.4mm [.25"]

Protect connection points or battery array connections  
Top lid allows for easy access to connection point  
Accepts up to 2/0 cables

956 Series Part No. Cable Entry Size  
- 956D9 — 17.8mm [.7"]

Colours Available:  
Colours Available:  
Colours Available:

TERMINAL INSULATORS SPECIALTY  
15  

---

## 16

Part No. Cable Entry Size  
- 422N9 — 15.2mm [.60"]

Part No. Cable Entry Size  
- 456N9 — Oval up to 4/0 ga

Part No. Cable Entry Size  
- 457N1 — 2.8mm [.11"]  
- 457N2 — 8.1mm [.32"]  
- 457N3 — 14.0mm [.55"]

Part No. Cable Entry Size  
- 419N9 — Open up to 1/0 ga

Part No. Cable Entry Size  
- 421N9 — 15.2mm [.60"]

The 419 Series is designed to protect multiple cable terminals.  
The insulator can slide back and forth to enable access to cable connections.  
Cable Entry: 13.8mm [0.53"]

The 421 Series is suited to protect offset battery terminals.  
Designed for use with negative terminals (black).  
Cable Entry: 15.2mm [0.60"]

421 Series

The 422 Series is designed for offset battery terminals.  
Commonly used on positive terminals (red).  
Cable Entry: 15.2mm [0.60"]

422 Series

The 456 Series offers protection on marine battery terminals.  
Works with bolt-on / wing-nut battery terminals.  
Accepts single or multiple cables.

456 Series

The 457 Series provides protection on marine battery terminals.  
Works with bolt-on / wing-nut battery terminals.  
Available in 3 sizes

457 Series

Adapter Insulators protect terminals that can detach the cable from the terminal, commonly found in the marine industry. Our terminal insulators help your company comply with various industry safety standards.

419 Series  
ADAPTER  

16  

TERMINAL INSULATORS  
www.vte.nl I Adapter Terminal Insulators  

TERMINAL INSULATORS METRIC RANGE TERMINAL BUSBARS FUSE HOLDERS POWER POSTS POWER BUSHINGS  

---

## 17

The 451 Series protects multiple cable adapter terminals.  
The insulator snaps onto the cable enabling easy removal.  
Cable Entry: 13.8mm [.53"]

451 Series Part No. Cable Entry Size  
- 451N9 — Open up to 1/0 ga  

The 453 Series is designed to protect offset adapter battery terminals.  
Commonly used with negative (black) terminals.  
Cable Entry: 12.7mm [.50"]

453 Series Part No. Cable Entry Size  
- 453L9 — Open up to 1/0 ga  
- 453D9 — Open up to 1/0 ga  

The 454 Series is suited to protect offset adapter battery terminals.  
Commonly used with positive (red) terminals.  
Cable Entry: 12.7mm [.50"]

454 Series Part No. Cable Entry Size  
- 454R9 — Open up to 1/0 ga  
- 454D9 — Open up to 1/0 ga  

\* ‘D’ Version allows cable to pass through insulator to next connection.

The 776 Series protects heavy duty battery terminals.  
Features a weatherproof insulator / cover kit.  
Can be used with filling material to make a waterproof solution.  
Includes 479 Series Disc:

776 Series Part No. Cable Entry Size  
- 776N7 — 10.7mm [.42"]  
- 776N8 — 15.8mm [.62"]  
- 776N9 — 20.8mm [.82"]  

The 484 Series is designed to protect right angle terminals.  
Available in regular (V) material - Thermoplastic Rubber (T).  
Cable Entry: 4/0 ga + sized cables.

484 Series Part No. Cable Entry Size  
- 484N9 — 4/0 ga + (30mm /1.18")  

\* ‘D’ Version allows cable to pass through insulator to next connection.

TERMINAL INSULATORS ADAPTER  
17 www.vte.nl I Adapter Terminal Insulators  

TERMINAL INSULATORS METRIC RANGE TERMINAL BUSBARS FUSE HOLDERS POWER POSTS POWER BUSHINGS  

---

## 18

Terminal Busbars: 3 Point & 4 Point  
Terminal Busbars: Large 4 Point & Dual 4 Point  
Terminal Busbars: 10 Point & 12 Point  
Terminal Busbars: Tab Type: 10, 20, 30, 40 Points  
Fuse Holders: ANL & High Amp ANL  
Fuse Holders: Mega & T Class  
Power Posts: Single Point Pass Thru & Waterproof Pass Thru  
Power Posts: Single Point - Low Profile, Small Base & Dual Post Holder  
Power Posts: Large Base, Heavy Duty & Eight Point  
Power Bushings: Copper Core  
Power Bushings: Copper Core Flange  
Power Bushings: Copper Core Jumper - Mounting Kits: Flush & Bracket  

Imperial Range  
Page 27  
Page 28  
Page 29  
Page 30  
Page 31  
Page 32  
Page 33  
Page 34  
Page 35  
Page 36  
Page 37  
Page 38  

ELECTRO-MECHANICAL

VTE offers a wide range of Electro-Mechanical devices for making secure connections, protecting components and wiring, distributing power, and extending power connections. These devices fill a void in the market place by providing high quality, low costs solution s.

The Electro-Mechanical range of products are rated for use up to 48 VDC. Other voltage ratings and current specifications are available on technical data sheets for each item on our website.

Our products are engineered with protection in mind, so that our products can be used in conjunction with our Terminal Insulators, to comply with common industry standards.

Where applicable, some of our products contain our Blue-Dot Technology. This technology indicates when a conductive fastener (nut) is utilised in place of a mechanical fastener. These conductive fasteners will carry current in a more efficient fashion and must be kept in their factory installed location.

Failure to keep the conductive fastener in its factory installed location will result in degraded performance.  
Failure to keep the mechanical fastener in its factory installed location can result in premature device failure.

INTRODUCTION

Power Posts: Single Point Pass Thru & Waterproof Pass Thru Power Posts: Single Point - Low Profile, Small Base & Dual Post Holder Power Posts: Large Base & Heavy Duty Power Bushings: Copper Core & Internal Thread Copper Core Power Bushings: Copper Core Flange Bushing Power Bushings: Copper Core Jumper Mounting Kits - Flush & Bracket

Terminal Busbars: Large 4 Point & Dual 4 Point  
Fuse Holders: ANL & High Amp ANL  

Metric Range  
Page 19  
Page 20  
Page 21  
Page 22  
Page 23  
Page 24  
Page 25  
Page 26  

CONTENTS

BLUE-DOT TECHNOLOGY  
OUR PVC’S ARE UL LISTED: V0 & V02. MOST OF OUR MATERIALS ARE ROHS & REACH COMPLIANT  
J2120 (2009 EDITION)  
Underwriters Laboratories -  

---

## 19

ELECTRO-MECHANICAL POWER POSTS  
METRIC  

19

Single Point Pass Thru Power Post

| Part Number | Post | Colour | Max Amps | Max Voltage |
|---|---|---|---:|---:|
| 77208N02 | M8 | Red | 250 | 48 VDC |
| 77208N05 | M8 | Yellow | 250 | 48 VDC |
| 77208N14 | M8 | Black | 250 | 48 VDC |
| 77210N02 | M10 | Red | 350 | 48 VDC |
| 77210N05 | M10 | Yellow | 350 | 48 VDC |
| 77210N14 | M10 | Black | 350 | 48 VDC |

Allows for multiple connections on either side of barrier  
Allows current to be passed through panel  
Corrosion resistant hardware  
Lower cost alternative to power bushing  
Easy Installation using regular drill bits  

Blue-Dot Technology

Maximum Panel Thickness: 9.53mm  
Maximum Voltage: 48 VDC  
Maximum Amperage: Ref Chart @ 12 VDC  

Base Material: Glass-Filled Nylon  
Post: Ni-Plated Brass  
Inner Nuts (Conductive): Tin-Plated Brass  
Outer Nuts (Fastening): Stainless Steel  
Spring Washers: Stainless Steel  
Flat Washer: Stainless Steel  

Using 956 Series & 226 Series terminal insulators help comply with ABYC, USCG and ISO standards.

Single Point Waterproof Pass Thru Power Post

* Waterproof to IP67+  
Pass current through a barrier - Max Thickness 9.53mm  
Corrosion resistant hardware  
Gasket and O-Ring Prevent Water & Dust  
O-Ring Mounting Screws  
Base Material: Glass-Filled Nylon  

Maximum Voltage: 48 VDC  
8mm Maximum Amperage: 250 Amps @ 12 VDC  
10mm Maximum Amperage: 350 Amps @ 12VDC  

Lower cost alternative to power bushing  

To help comply with ABYC, USCG & ISO standards - Use 220N Series (front) & 226N Series (back) insulators  

* In house testing to IP67 specifications

WATER PROOF

Part Number Post Colour  
- 77208W02 — M8 — Red — 250 — 48 VDC  
- 77208W05 — M8 — Yellow — 250 — 48 VDC  
- 77208W14 — M8 — Black — 250 — 48 VDC  
- 77210W02 — M10 — Red — 350 — 48 VDC  
- 77210W05 — M10 — Yellow — 350 — 48 VDC  
- 77210W14 — M10 — Black — 350 — 48 VDC  

Power distribution posts offer a quick and low cost solution to getting power to your devices. We offer several lines of distribution posts, for passing current through a barrier, distributing power to several devices, or allowing for power connections outside a device. All our connection devices offer terminal insulation solutions, to keep your products compliant with industry safety regulations.

BLUE-DOT TECHNOLOGY  
Max Amps Max Voltage  
IP67 *  

www.vte.nl I Power Posts  

NEW!  
TERMINAL INSULATORS TERMINAL BUSBARS FUSE HOLDERS POWER POSTS POWER BUSHINGS  

---

## 20

POWER POSTS  
METRIC  

Single Point Power Post - Low Profile

| Part Number | Post | Amps* | Colour | Base Size |
|---|---|---:|---|---|
| 77306N02 | M6 | 150 | Red | Small |
| 77306N14 | M6 | 150 | Black | Small |
| 77308N02 | M8 | 190 | Red | Small |
| 77308N14 | M8 | 190 | Black | Small |

Lower height than our 770 Series  
Corrosion resistant stainless steel hardware  
Connect two or more voltage lines  
Hook up negative return lines to single cable  

Maximum Voltage: 48 VDC  
Maximum Amperage: 190 Amps @ 12 VDC  

*Amperage ratings are for reference only. Current capacity is determined by the cables used, not the junction post. Current ratings relate to expected cable capacities.

All Hardware: Stainless Steel  
Base Material: Glass-Filled Nylon  

20

---

## 21

POWER POSTS  
METRIC  

Part Number Post Amps* Colour Base Size  
- 77008N02 — M8 — 190 — Red — Small  
- 77008N05 — M8 — 190 — Yellow — Small  
- 77008N14 — M8 — 190 — Black — Small  

Single Point Power Post - Small Base  
Dual Small Base Power Post Holder

Part Number Description Colour Base Size  
- 72770000 — Dual Post Holder — Black — Small  

Compact system to mount 2 single point power posts  
Raised mounting platform allows moisture to escape  
Safety divider reduces risk of shorts & arcs during install  
Power posts can be unscrewed from holder & replaced  
Holder fastened by 4 machine screws  
Provides option for power posts with dissimilar stud sizes  
Compatible with all 770 & 773 series power posts  
770 & 773 Series Power Posts - Sold Separately  
Release Date: Q4 2026  

www.vte.nl I Power Posts  

TERMINAL INSULATORS METRIC RANGE TERMINAL BUSBARS FUSE HOLDERS POWER POSTS POWER BUSHINGS  

---

## 22

ELECTRO-MECHANICAL POWER POSTS  
METRIC

Part Number Post Amps* Colour Base Size  
- 77108N02 — M8 — 190 — Red — Large  
- 77108N14 — M8 — 190 — Black — Large  

All Hardware: Stainless Steel  
Base Material: Glass-Filled Nylon  
Maximum Voltage: 48 VDC  
Maximum Amperage: 160 Amps @ 12 VDC  

Connect two or more voltage lines  
Hook up negative return lines to single cable  

*Amperage ratings are for reference only. Current capacity is determined by the cables used, not the junction post. Current ratings relate to expected cable capacities.

Single Point Power Post - Heavy Duty

Part Number Post Amps* Colour Base Size  
- 77510M0N02 — M10 — 240 — Red — H/Duty  
- 77510M0N14 — M10 — 240 — Black — H/Duty  
- 77512M0N02 — M12 — 300 — Red — H/Duty  
- 77512M0N14 — M12 — 300 — Black — H/Duty  

Strong stable base tolerates heavy torque & pulling force  
All Hardware: Stainless Steel  
Base Material: Glass-Filled Nylon  
Maximum Voltage: 48 VDC  
Maximum Amperage: 250 Amps @ 12 VDC  

Connect two or more voltage lines  
Hook up negative return lines to single cable  
Flexible mounting orientation  

*Amperage ratings are for reference only. Current capacity is determined by the cables used, not the junction post. Current ratings relate to expected cable capacities.

21  
INSULATION PACKAGES  
Contact us for further details on available insulation packages or please visit our website www.vte.nl

TERMINAL INSULATORS METRIC RANGE TERMINAL BUSBARS FUSE HOLDERS POWER POSTS POWER BUSHINGS  

---

## 23

ELECTRO-MECHANICAL  

POWER BUSHINGS  
METRIC

Copper Core Power Bushing  
High energy transfer and High torque capabilities  
High Anti-Rotation  

Maximum Panel Thickness: 9.5mm  
Maximum Voltage: 48 VDC  

Bushing Material: Glass-Filled Nylon  
Post Material: Nickel-Plated Steel  

Weatherproof part (”W”) includes:  
- (1)x 358N Series sealing ring & (1)x 258N9 Series insulator  
- (1)x 358N Series sealing ring & (1)x 258N4 Series insulator (as listed)

| Part Number | Post | Amperages | Colour | Weather Proof |
|---|---|---|---|---|
| CCB108N02 | M10 | Norm:600 - Peak:750 | Red | No |
| CCB108N02W | M10 | Norm:600 - Peak:750 | Red | Yes |
| CCB108N05 | M10 | Norm:600 - Peak:750 | Yellow | No |
| CCB108N05W | M10 | Norm:600 - Peak:750 | Yellow | Yes |
| CCB108N14 | M10 | Norm:600 - Peak:750 | Black | No |
| CCB108N14W | M10 | Norm:600 - Peak:750 | Black | Yes |
| CCB126N02 | M12 | Norm:440 - Peak:550 | Red | No |
| CCB126N02W | M12 | Norm:440 - Peak:550 | Red | Yes |
| CCB126N05 | M12 | Norm:440 - Peak:550 | Yellow | No |
| CCB126N05W | M12 | Norm:440 - Peak:550 | Yellow | Yes |
| CCB126N14 | M12 | Norm:440 - Peak:550 | Black | No |
| CCB126N14W | M12 | Norm:440 - Peak:550 | Black | Yes |
| CCB376M0N05 | M10 | Norm:360 - Peak:450 | Yellow | No |
| CCB376M0N05W | M10 | Norm:360 - Peak:450 | Yellow | Yes |
| CCB376M0N07 | M10 | Norm:360 - Peak:450 | Green | No |
| CCB376M0N14 | M10 | Norm:360 - Peak:450 | Black | No |
| CCB376M0N14W | M10 | Norm:360 - Peak:450 | Black | Yes |
| CCB376M0NR02 | M10 | Norm:360 - Peak:450 | Red | No |
| CCB376M0NR02W | M10 | Norm:360 - Peak:450 | Red | Yes |

POWER BUSHINGS WEATHER PROOF KIT

Proof Kit Part Number Post Ring Terminal Capacity** Colour  
ICB086N02 — M8 — (2) 16mm - Min 0 - Max 4.5mm — Red  
ICB086N05 — M8 — (2) 16mm - Min 0 - Max 4.5mm — Yellow  
ICB086N07 — M8 — (2) 16mm - Min 0 - Max 4.5mm — Green  
ICB086N09 — M8 — (2) 16mm - Min 0 - Max 4.5mm — Blue  
ICB086N13 — M8 — (2) 16mm - Min 0 - Max 4.5mm — Grey  
ICB086N14 — M8 — (2) 16mm - Min 0 - Max 4.5mm — Black  

Internal Thread Copper Core Power Bushing  
* Waterproof to IP67+  
High conductivity with low heat buildup  
Corrosion resistant stainless steel hardware  
Silicone rubber gasket  

Maximum Voltage: 48 VDC  
Bushing Material: Glass-Filled Nylon  
Maximum Panel Thickness: 9.5mm  

Low profile installations  
To help comply with ABYC, USCG & ISO standards - Use 232 Series (pg 04) or 487 Series Insulators (pg 07)

* In house testing to IP67 specifications  

WATER PROOF Proof Kit Weather  

**16mm bolt length allows for ring terminal connection capacity from 0mm - 4.5mm. If greater capacity required, please contact us or refer to the relevant ICB chart on our website www.vte.nl  

www.vte.nl I Power Bushings  

TERMINAL INSULATORS METRIC RANGE TERMINAL BUSBARS FUSE HOLDERS POWER POSTS POWER BUSHINGS  

---

## 24

POWER BUSHINGS  
METRIC  
ELECTRO-MECHANICAL

Copper Core Flange Bushing  
WEATHER PROOF KIT  

Proof Kit  
Weather  

Part Number Post Amperages Colour  
CCFB106N02 — M10 — Norm:360 - Peak:450 — Red  
CCFB106N02W — M10 — Norm:360 - Peak:450 — Red  
CCFB106N05 — M10 — Norm:360 - Peak:450 — Yellow  
CCFB106N05W — M10 — Norm:360 - Peak:450 — Yellow  
CCFB106N14 — M10 — Norm:360 - Peak:450 — Black  
CCFB106N14W — M10 — Norm:360 - Peak:450 — Black  
CCFB108N02 — M10 — Norm:600 - Peak:750 — Red  
CCFB108N02W — M10 — Norm:600 - Peak:750 — Red  
CCFB108N05 — M10 — Norm:600 - Peak:750 — Yellow  
CCFB108N05W — M10 — Norm:600 - Peak:750 — Yellow  
CCFB108N14 — M10 — Norm:600 - Peak:750 — Black  
CCFB108N14W — M10 — Norm:600 - Peak:750 — Black  
CCFB126N02 — M12 — Norm:440 - Peak:550 — Red  
CCFB126N02W — M12 — Norm:440 - Peak:550 — Red  
CCFB126N05 — M12 — Norm:440 - Peak:550 — Yellow  
CCFB126N05W — M12 — Norm:440 - Peak:550 — Yellow  
CCFB126N14 — M12 — Norm:440 - Peak:550 — Black  
CCFB126N14W — M12 — Norm:440 - Peak:550 — Black  

High energy transfer and High torque capabilities  
High Anti-Rotation  
Maximum Panel Thickness: 9.53mm  
Maximum Voltage: 48 VDC  

Bushing Material: Glass-Filled Nylon  
Fastener (Nut) Material: Stainless Steel  
Post Material: Nickel-Plated Steel  

Weatherproof part (”W”) includes:  
(1)x reinforced silicone gasket & (1)x 232N3 Series insulator

www.vte.nl I Power Bushings  

TERMINAL INSULATORS METRIC RANGE TERMINAL BUSBARS FUSE HOLDERS POWER POSTS POWER BUSHINGS  

---

## 25

24 POWER BUSHINGS  
METRIC  
ELECTRO-MECHANICAL

1x Red Copper Core Jumper Bushing  
1x Black Copper Core Jumper Bushing  
1x Adhesive Decal for installation drilling guide  
1x Protection Divider with Screws (2)

Copper Core Jumper - Flush Mount Kit  
Part Number Post Amps Max Voltage Colour  
CCJB376FMKM — M10 — 350 — 48 VDC — Red & Black  

1x Red Copper Core Jumper Bushing  
1x Black Copper Core Jumper Bushing  
1x Protection Divider with Screws (2)  
1x Mounting Bracket - Powder Coated & Pre-drilled

Copper Core Jumper - Bracket Mount Kit

Copper Core Bushing  
Part Number Post Amps Max Voltage Colour  
CCJB376M0N14 — M10 — 350 — 48 VDC — Black  
CCJB376M0NR02 — M10 — 350 — 48 VDC — Red  

High energy transfer and High torque capabilities  
High Anti-Rotation  
Maximum Panel Thickness: 9.53mm  
Maximum Voltage: 48 VDC  

Bushing Material: Glass-Filled Nylon  
Post Material: Nickel Plated Mild Steel  
Hex Cap Material: Brass  

Includes post insulator  
An effective solution to jumpstarting devices and for providing remote charging capabilities. The copper core is cold swaged into a hex shape equipping high energy transfer performance.

All Jumper Bushings are compatible with common ‘Double D’ punches to increase anti-rotation characteristics.

MOUNT KIT INCLUDED  

Part Number Post Amps Max Voltage Colour  
CCJB376BMKM — M10 — 350 — 48 VDC — Red & Black  

www.vte.nl I Power Bushings  

TERMINAL INSULATORS METRIC RANGE TERMINAL BUSBARS FUSE HOLDERS POWER POSTS POWER BUSHINGS  
TERMINAL BUSBARS

## 26

### ELECTRO-MECHANICAL TERMINAL BUSBARS (METRIC)
Whether you need to connect a few high amperage cables, or many low amperage connections in a fast-paced production environment, VTE has a device to fit your application. Ranging from 3 up to 30 connection points, and capable of handling up to 750 amps, you're sure to find a solution to fit your needs.

Our Large 4 Point Terminal Busbar allows for multiple connections to positive and negative systems. Each connection post can maintain multiple connections, making them flexible and robust.

#### Large 4 Point Terminal Busbar
Part Number | Post | Max Amps @ 12 VDC | Colour
---|---|---|---
74008N0N02 | M8 | 250 | Red
74008N0N14 | M8 | 250 | Black
74008N1N02 | M8 | 250 | Red
74008N1N14 | M8 | 250 | Black
74010N0N02 | M10 | 250 | Red
74010N0N14 | M10 | 250 | Black
74010N1N02 | M10 | 250 | Red
74010N1N14 | M10 | 250 | Black

- Nickel-plated brass plate for increased current transfer  
- Connection Posts, Hex Nuts and Washers: Stainless steel  
- Base material: 16% glass-filled nylon (red & black)  
- Overall length: 164.36mm  
- Mounting centre: 145.06mm  

OPTIONAL COVER KIT

Whether you need to connect a few high amperage cables, or many low amperage connections in a fast-paced production environment, VTE has a device to fit your application. Ranging from 3 up to 30 connection points, and capable of handling up to 750 amps, you're sure to find a solution to fit your needs.

Our Large 4 Point Terminal Busbar allows for multiple connections to positive and negative systems. Each connection post can maintain multiple connections, making them flexible and robust.

#### Dual 4 Point Terminal Busbar
Part Number | Side 1 | Side 2 | Max Amps | Colour
---|---|---|---|---
738808N0N02 | M8 | M8 | 250 | Red
738808N0N14 | M8 | M8 | 250 | Black
738N3P14 |  |  |  | Black
738808N1N14 |  |  |  | Black
738N3P05 |  |  |  | Yellow

- Optional Cover  
- Multiple points, to accommodate various connections  
- Secure way to consolidate positive and negative systems  
- Maximum Voltage: 48 VDC  
- Maximum Amperage: 250 Amps total @ 12 VDC  
- (3) additional 20 Amp connection screws per side  
- Hex Nuts & Washers: Stainless steel  
- Base material: 16% glass-filled nylon  
- Overall Length: 145.3mm  
- Mounting Centre: 124.5mm  
- Mounting Screws: #10 (Not Included)

Optional Kit Inc: (1) 723N3 - (2) Retaining Nuts  
Optional Kit Inc: (1) 723N7 - (2) Retaining Nuts  
Optional Kit Inc: (1) 723N4 - (2) Retaining Nuts  
Optional Kit Inc: (1) 723N8 - (2) Retaining Nuts  
Optional Kit Inc: (1) 738808N0 - (1) 738N3P14  

www.vte.nl I Terminal Busbars

## 27

### ELECTRO-MECHANICAL FUSE HOLDERS (IMPERIAL)

We offer a large range of fuse holders to suit most fuse types. These allow you to protect medium and high amperage devices, such as winches, pumps, motors and other heavy draw devices.

#### ANL Fuse Holder
Part Number | Cover Kit Includes | Colour
---|---|---
ANB740M0N02 | 12.7mm (0.5") (1) 342N0 -(2) 487N6 Insulators | Red
ANB740M0N14 | 12.7mm (0.5") (1) 342N0 -(2) 487N6 Insulators | Black
ANB740M10N02 | 15.2mm (0.6") (1) 342N0 -(2) 487N7 Insulators | Red
ANB740M10N14 | 15.2mm (0.6") (1) 342N0 -(2) 487N7 Insulators | Black

Part Number | Post | Amps Includes | Colour
---|---|---|---
ANB753M9N02 | M10 | 750 | Red
ANB753M9N14 | M10 | 750 | Black

High Amp ANL Fuse Holder
Secure your ANL fuses with VTE ANL Fuse Holders

Cost effective solution for 50 - 300 Amp Fusing  
Cable Diameter: 19.1mm (0.75")  
Maximum Holder Voltage: 48 VDC  
Base Material: Glass-Filled Nylon  
Connection Post Material: Stainless Steel  
Lock Washer: Stainless Steel  
Flat Washer: Brass  
Accommodates large & narrow slot ANL Fuses  
Also available in 5/16" Post Size (Pg 31)

COVER KIT INCLUDED  
FUSE HOLDER INCLUDED  
Fuses Not Supplied  

Cost Effective Solution For Up to 750 Amp Fusing  
Post Sizes Available: M10, 5/16" and 3/8" (pg 31)  
Maximum Voltage: 32 VDC  
Base Material: Glass-Filled Nylon  
Connection Post Material: Stainless Steel  
Lock Washer Material: Stainless Steel  
Flat Washer Material: Stainless Steel  
Conductive Spacer Material: Nickel-Plated Copper  
Included cover helps comply with safety regulations  
High Amperage Fuses Not Supplied

BLUE-DOT TECHNOLOGY  
Fuses Not Supplied

www.vte.nl I Fuse Holders

## 28

### FUSE HOLDERS (IMPERIAL)
Cost effective solution to Mega Fuse protection  
Maximum Voltage: 32 VDC  
Holder Post: 5/16” (7.93mm) Stainless Steel  
Flat Washers: Brass  
Connection Fastener Nut: Stainless Steel  
Base Material: Glass-Filled Nylon  
When used with 405 Series Terminal Insulators it helps comply with safety regulations  
Accepts 60 - 250 Fuse Amperages

Mega Fuse Holder
Part Number | Kit Includes | Colour
---|---|---
MFB736N9N02 | 12.7mm (0.5") (2) 405N9V02 Insulators | Red
MFB736N9N14 | 12.7mm (0.5") (2) 405N9V14 Insulators | Black

Cable Diameter
KIT INCLUDED

Commonly used for equipment protection  
Holder Voltage Rating: 48 VDC  
3/8” Stud accepts lug/ring terminals up to 4/0 AWG (103mm2)  
Connection Stud: Stainless Steel  
Connection Fastener Nut: Stainless Steel  
Washers: Stainless Steel  
Base Material: Glass-Filled Nylon  
Fuses Sold Separately  

Cost effective solution for securing Class T Fuses  
Optional cover helps comply with safety regulations

#### T-Class Fuse Holder
Part Number | Post | Maximum Amperage | Colour
---|---|---|---
TFB735N0N02 | 3/8" | 400 Amps @ 12 VDC | Red
TFB735N0N14 | 3/8" | 400 Amps @ 12 VDC | Black
TFB735N8N02 | 3/8" | Kit: (1) TFB735N0N02 -(1) 751N8P00 | Red
TFB736N8N14 | 3/8" | Kit: (1) TFB735N0N14 -(1) 751N8P00 | Black

751N8P00 Clear

COVER KIT INCLUDED  
Optional Cover  
Fuses Not Supplied  
www.vte.nl I Fuse Holders

## 29

### POWER POSTS (IMPERIAL) — ELECTRO-MECHANICAL

Single Point Pass Thru Power Post

Part Number | Post | Colour
---|---|---
77225N02 | 1/4" | 150 | 0-48 VDC Red
77225N05 | 1/4“ | 150 | 0-48 VDC Yellow
77225N09 | 1/4“ | 150 | 0-48 VDC Blue
77225N14 | 1/4“ | 150 | 0-48 VDC Black
77231N02 | 5/16" | 250 | 0-48 VDC Red
77231N05 | 5/16" | 250 | 0-48 VDC Yellow
77231N09 | 5/16" | 250 | 0-48 VDC Blue
77231N14 | 5/16" | 250 | 0-48 VDC Black
77237N02 | 3/8" | 350 | 0-48 VDC Red
77237N05 | 3/8" | 350 | 0-48 VDC Yellow
77237N09 | 3/8" | 350 | 0-48 VDC Blue
77237N14 | 3/8” | 350 | 0-48 VDC Black

Allows for multiple connections on either side of barrier  
Allows current to be passed through panel  
Corrosion resistant hardware  
Lower cost alternative to power bushing  
Easy Installation using regular drill bits  
Blue-Dot Technology  
Maximum Panel Thickness: 9.53mm  
Maximum Voltage: 48 VDC  
Maximum Amperage: Ref Chart @ 12 VDC  
Base Material: Glass-Filled Nylon  
Using 956 Series & 226 Series terminal insulators help comply with ABYC, USCG and ISO standards.  
Post: Ni-Plated Brass  
Inner Nuts (Conductive): Tin-Plated Brass  
Outer Nuts (Fastening): Stainless Steel  
Spring Washers: Stainless Steel  
Flat Washer: Stainless Steel

Single Point Waterproof Pass Thru Power Post
* Waterproof to IP67+

Pass current through a barrier - Max Thickness 9.53mm  
Corrosion resistant hardware  
Gasket and O-Ring Prevent Water & Dust  
O-Ring Mounting Screws  
Base Material: Glass-Filled Nylon  
Maximum Voltage: 48 VDC  
5/16" Maximum Amperage: 250 Amps @ 12 VDC  
3/8" Maximum Amperage: 350 Amps @ 12VDC  
Lower cost alternative to power bushing  
To help comply with ABYC, USCG & ISO standards - Use 220N Series (front) & 226N Series (back) insulators  
* In house testing to IP67 specifications

WATER PROOF
Part Number | Post | Colour
---|---|---
77231W02 | 5/16" | 250 0-48 VDC Red
77231W05 | 5/16" | 250 0-48 VDC Yellow
77231W14 | 5/16" | 250 0-48 VDC Black
77237W02 | 3/8" | 350 0-48 VDC Red
77237W05 | 3/8" | 350 0-48 VDC Yellow
77237W14 | 3/8" | 350 0-48 VDC Black

BLUE-DOT TECHNOLOGY  
MaxAmps Max Voltage

POWER POSTS

www.vte.nl I Power Posts

## 30

### POWER POSTS (IMPERIAL) — ELECTRO-MECHANICAL

Single Point Power Post - Low Profile
Part Number | Post | Amps* | Colour | Base Size
---|---|---|---|---
77325N02 | 1/4" | 150 | Red | Small
77325N14 | 1/4" | 150 | Black | Small
77331N02 | 5/16" | 190 | Red | Small
77331N14 | 5/16" | 190 | Black | Small
77337N02 | 3/8" | 240 | Red | Small
77337N14 | 3/8" | 240 | Black | Small

Lower height than our 770 Series  
Corrosion resistant stainless steel hardware  
Connect two or more voltage lines  
Hook up negative return lines to single cable  
Maximum Voltage: 48 VDC  
Maximum Amperage: Ref to Chart @ 12 VDC  
*Amperage ratings are for reference only. Current capacity is determined by the cables used, not the junction post. Current ratings relate to expected cable capacities.

All Hardware: Stainless Steel  
Base Material: Glass-Filled Nylon  
Maximum Voltage: 48 VDC  
Maximum Amperage: Ref to Chart @ 12 VDC  
Connect two or more voltage lines  
Hook up negative return lines to single cable  
*Amperage ratings are for reference only. Current capacity is determined by the cables used, not the junction post. Current ratings relate to expected cable capacities.

Part Number | Post | Amps* | Colour | Base Size
---|---|---|---|---
77010N02 | #10 | 30 | Red | Small
77010N14 | #10 | 30 | Black | Small
77025N02 | 1/4" | 150 | Red | Small
77025N14 | 1/4" | 150 | Black | Small
77031N02 | 5/16" | 190 | Red | Small
77031N05 | 5/16" | 190 | Yellow | Small
77031N09 | 5/16" | 190 | Blue | Small
77031N14 | 5/16" | 190 | Black | Small
77037N02 | 3/8" | 240 | Red | Small
77037N14 | 3/8" | 240 | Black | Small

Single Point Power Post - Small Base
Dual Small Base Power Post Holder
Part Number | Description | Colour | Base Size
---|---|---|---
72770000 | Dual Post Holder | Black | Small

Compact system to mount 2 single point power posts  
Raised mounting platform allows moisture to escape  
Safety divider reduces risk of shorts & arcs during install  
Power posts can be unscrewed from holder & replaced  
Holder fastened by 4 machine screws  
Provides option for power posts with dissimilar stud sizes  
Compatible with all 770 & 773 series power posts  
770 & 773 Series Power Posts - Sold Separately  

Release Date: Q4 2026

POWER POSTS

www.vte.nl I Power Posts

## 31

### POWER POSTS (IMPERIAL)

Single Point Power Post - Large Base
Part Number | Post | Amps* | Colour | Base Size
---|---|---|---|---
77125N02 | 1/4" | 150 | Red | Large
77125N14 | 1/4" | 150 | Black | Large
77131N02 | 5/16" | 190 | Red | Large
77131N14 | 5/16" | 190 | Black | Large
77137N02 | 3/8" | 240 | Red | Large
77137N14 | 3/8" | 240 | Black | Large

All Hardware: Stainless Steel  
Base Material: Glass-Filled Nylon  
Maximum Voltage: 48 VDC  
Maximum Amperage: Ref to Chart @ 12 VDC  
Connect two or more voltage lines  
Hook up negative return lines to single cable  
*Amperage ratings are for reference only. Current capacity is determined by the cables used, not the junction post. Current ratings relate to expected cable capacities.

Single Point Power Post - Heavy Duty
Part Number | Post | Amps* | Colour | Base Size
---|---|---|---|---
77512N0N02 | 1/2" | 300 | Red | H/Duty
77512N0N14 | 1/2" | 300 | Black | H/Duty

All Hardware: Stainless Steel  
Base Material: Glass-Filled Nylon  
Maximum Voltage: 48 VDC  
Maximum Amperage: Ref to Chart @ 12 VDC  
Connect two or more voltage lines  
Hook up negative return lines to single cable  
*Amperage ratings are for reference only. Current capacity is determined by the cables used, not the junction post. Current ratings relate to expected cable capacities.

Eight Point Power Post
Part Number | Post | Amps* | Colour
---|---|---|---
77825N02 | 1/4" | 160 | Red
77825N14 | 1/4" | 160 | Black
77831N02 | 5/16" | 160 | Red
77831N14 | 5/16" | 160 | Black
77837N02 | 3/8" | 160 | Red
77837N14 | 3/8" | 160 | Black

BLUE-DOT TECHNOLOGY  
Base Material: Glass-Filled Nylon  
Connection Post: Stainless Steel  
Conductive Disk: Nickel-Plated Copper Alloy  
Conductive Nuts: Tin-Plated Copper Alloy  
Mechanical Fastener Nuts: Stainless Steel  
Create reliable circuit paths to control systems  
(8) #8-32 Connection points carry up to 20 amps each @ 12 VDC  
Maximum Voltage: 48 VDC  
Mounting Centre: 63.5mm [2.5"]  
Insulation Kits available with 1, 2 or multiple cable entry

INSULATION PACKAGES
1 Cable: 228N3 Insulator 2 Cables: 956D9 Insulator Multi Cables: 795V Insulator  
Multi Cables: 795 Insulator

Contact us for further details on available insulation packages or please visit our website www.vte.nl

INSULATION PACKAGES
Contact us for further details on available insulation packages or please visit our website www.vte.nl

POWER POSTS

Dual Cable: 956 Insulator Dual Cable: 375 Insulator Multi Cable: 795 Insulator Multi Cables: 375 Insulator

www.vte.nl I Power Posts

## 32

### POWER BUSHINGS (IMPERIAL)

We have developed a new solution to jumpstarting devices and for providing remote charging capabilities. Our Copper Core Jumper Bushings provide high current passing properties along with high torque strength.

Copper Core Power Bushing  
High energy transfer and High torque capabilities  
High Anti-Rotation  
Maximum Panel Thickness: 9.5mm  
Maximum Voltage: 48 VDC  
Bushing Material: Glass-Filled Nylon  
Post Material: Nickel-Plated Steel  
Weatherproof part (“W”) includes:  
(1)x 358N Series sealing ring & (1)x 258N4 Series insulator  
(1)x 358N Series sealing ring & (1)x 258N9 Series insulator  

Part Number | Post | Amperages | Colour
---|---|---|---
CCB376N0N02 | 3/8" | Norm:440 - Peak:550 | Red
CCB376N0N02W | 3/8" | Norm:440 - Peak:550 | Red
CCB376N0N05 | 3/8" | Norm:440 - Peak:550 | Yellow
CCB376N0N05W | 3/8" | Norm:440 - Peak:550 | Yellow
CCB376N0N14 | 3/8" | Norm:440 - Peak:550 | Black
CCB376N0N14W | 3/8" | Norm:440 - Peak:550 | Black
CCB376N0NR02 | 3/8" | Norm:440 - Peak:550 | F/Red
CCB376N0NR02W | 3/8" | Norm:440 - Peak:550 | F/Red
CCB376N1N02W | 3/8" | Norm:440 - Peak:550 | Red
CCB376N1N14W | 3/8" | Norm:440 - Peak:550 | Black
CCB376N1NR02W | 3/8" | Norm:440 - Peak:550 | F/Red
CCB378N02 | 3/8" | Norm:600 - Peak:750 | Red
CCB378N02W | 3/8" | Norm:600 - Peak:750 | Red
CCB378N05 | 3/8" | Norm:600 - Peak:750 | Yellow
CCB378N05W | 3/8" | Norm:600 - Peak:750 | Yellow
CCB378N14 | 3/8" | Norm:600 - Peak:750 | Black
CCB378N14W | 3/8" | Norm:600 - Peak:750 | Black
CCB506N02 | 1/2" | Norm:440 - Peak:550 | Red
CCB506N02W | 1/2" | Norm:440 - Peak:550 | Red
CCB506N05 | 1/2" | Norm:440 - Peak:550 | Yellow
CCB506N05W | 1/2" | Norm:440 - Peak:550 | Yellow
CCB506N14 | 1/2" | Norm:440 - Peak:550 | Black
CCB506N14W | 1/2" | Norm:440 - Peak:550 | Black
CCB516N02W | 1/2" | Norm:440 - Peak:550 | Red
CCB516N09W | 1/2" | Norm:440 - Peak:550 | Blue
CCB516N13W | 1/2" | Norm:440 - Peak:550 | Grey
CCB516N14W | 1/2" | Norm:440 - Peak:550 | Black

WEATHER PROOF  
www.vte.nl I Power Bushings

TERMINAL INSULATORS METRIC RANGE TERMINAL BUSBARS FUSE HOLDERS POWER POSTS POWER BUSHINGS

## 33

### POWER BUSHINGS (IMPERIAL)

Proof Water
Copper Core Flange Bushing  
High energy transfer and High torque capabilities  
High Anti-Rotation  
Maximum Panel Thickness: 9.53mm  
Maximum Voltage: 48 VDC  
Bushing Material: Glass-Filled Nylon  
Fastener (Nut) Material: Stainless Steel  
Post Material: Nickel-Plated Steel  
Weatherproof part (“W”) includes:  
(1)x reinforced silicone gasket & (1)x 232N3 Series insulator  

Part Number | Post | Amperages | Colour
---|---|---|---
CCFB376N02 | 3/8" | Norm:440 - Peak:550 | Red
CCFB376N02W | 3/8" | Norm:440 - Peak:550 | Red
CCFB367N05 | 3/8" | Norm:440 - Peak:550 | Yellow
CCFB376N05W | 3/8" | Norm:440 - Peak:550 | Yellow
CCFB376N14 | 3/8" | Norm:440 - Peak:550 | Black
CCFB376N14W | 3/8" | Norm:440 - Peak:550 | Black
CCFB378N02 | 3/8" | Norm:600 - Peak:750 | Red
CCFB378N02W | 3/8" | Norm:600 - Peak:750 | Red
CCFB378N05 | 3/8" | Norm:600 - Peak:750 | Yellow
CCFB378N05W | 3/8" | Norm:600 - Peak:750 | Yellow
CCFB378N14 | 3/8" | Norm:600 - Peak:750 | Black
CCFB378N14W | 3/8" | Norm:600 - Peak:750 | Black
CCFB506N02 | 1/2" | Norm:440 - Peak:550 | Red
CCFB506N02W | 1/2" | Norm:440 - Peak:550 | Red
CCFB506N05 | 1/2" | Norm:440 - Peak:550 | Yellow
CCFB506N05W | 1/2" | Norm:440 - Peak:550 | Yellow
CCFB506N14 | 1/2" | Norm:440 - Peak:550 | Black
CCFB506N14W | 1/2" | Norm:440 - Peak:550 | Black

WEATHER PROOF KIT  
CCFB Mounted:  
Mounts with Bolts or Screws

Our Copper Core Flange Bushing utilises the same copper core as our CCB, to pass current through a panel.  
The bushing is fastened by 4 screws or bolts and has insulator retention grooves to provide a secure fit for terminal insulators on both sides.

www.vte.nl I Power Bushings

TERMINAL INSULATORS METRIC RANGE TERMINAL BUSBARS FUSE HOLDERS POWER POSTS POWER BUSHINGS

## 34

### POWER BUSHINGS (IMPERIAL)

1x Red Copper Core Jumper Bushing  
1x Black Copper Core Jumper Bushing  
1x Adhesive Decal for installation drilling guide  
1x Protection Divider with Screws (2)

Copper Core Jumper - Flush Mount Kit  
Part Number | Post | Amps Max Voltage | Colour
---|---|---|---
CCJB376FMK | 3/8" | 350 48 VDC | Red & Black

1x Red Copper Core Jumper Bushing  
1x Black Copper Core Jumper Bushing  
1x Protection Divider with Screws (2)

Copper Core Jumper - Bracket Mount Kit

Copper Core Jumper Bushing  
Part Number | Post | Amps Max Voltage | Colour
---|---|---|---
CCJB376N0NR02 | 3/8" | 350 48 VDC | Red
CCJB376N0N14 | 3/8" | 350 48 VDC | Black

High energy transfer and High torque capabilities  
High Anti-Rotation  
Maximum Panel Thickness: 9.53mm  
Maximum Voltage: 48 VDC  
Pass electrical current through a barrier or panel  
Bushing Material: Glass-Filled Nylon  
Post Material: Nickel Plated Mild Steel  
Hex Cap Material: Brass  
Includes post insulator, which helps comply with safety regulations

MOUNT KIT INCLUDED  
MOUNT KIT INCLUDED

Part Number | Post | Amps Max Voltage | Colour
---|---|---|---
CCJB376BMK | 3/8" | 350 48 VDC | Red & Black

www.vte.nl I Power Bushings

TERMINAL INSULATORS METRIC RANGE TERMINAL BUSBARS FUSE HOLDERS POWER POSTS POWER BUSHINGS

## 35

### ELECTRO-MECHANICAL (IMPERIAL)
POWER POSTS

We have developed a new solution to jumpstarting devices and for providing remote charging capabilities.
Our Copper Core Jumper Bushings provide high current passing properties along with high torque strength.

Copper Core Power Bushing  
High energy transfer and High torque capabilities  
High Anti-Rotation  
Maximum Panel Thickness: 9.5mm  
Maximum Voltage: 48 VDC  
Bushing Material: Glass-Filled Nylon  
Post Material: Nickel-Plated Steel  
Weatherproof part (“W”) includes:  
(1)x 358N Series sealing ring & (1)x 258N4 Series insulator  
(1)x 358N Series sealing ring & (1)x 258N9 Series insulator  

Part Number | Post | Amperages | Colour
---|---|---|---
CCB376N0N02 | 3/8" | Norm:440 - Peak:550 | Red
CCB376N0N02W | 3/8" | Norm:440 - Peak:550 | Red
CCB376N0N05 | 3/8" | Norm:440 - Peak:550 | Yellow
CCB376N0N05W | 3/8" | Norm:440 - Peak:550 | Yellow
CCB376N0N14 | 3/8" | Norm:440 - Peak:550 | Black
CCB376N0N14W | 3/8" | Norm:440 - Peak:550 | Black
CCB376N0NR02 | 3/8" | Norm:440 - Peak:550 | F/Red
CCB376N0NR02W | 3/8" | Norm:440 - Peak:550 | F/Red
CCB376N1N02W | 3/8" | Norm:440 - Peak:550 | Red
CCB376N1N14W | 3/8" | Norm:440 - Peak:550 | Black
CCB376N1NR02W | 3/8" | Norm:440 - Peak:550 | F/Red
CCB378N02 | 3/8" | Norm:600 - Peak:750 | Red
CCB378N02W | 3/8" | Norm:600 - Peak:750 | Red
CCB378N05 | 3/8" | Norm:600 - Peak:750 | Yellow
CCB378N05W | 3/8" | Norm:600 - Peak:750 | Yellow
CCB378N14 | 3/8" | Norm:600 - Peak:750 | Black
CCB378N14W | 3/8" | Norm:600 - Peak:750 | Black
CCB506N02 | 1/2" | Norm:440 - Peak:550 | Red
CCB506N02W | 1/2" | Norm:440 - Peak:550 | Red
CCB506N05 | 1/2" | Norm:440 - Peak:550 | Yellow
CCB506N05W | 1/2" | Norm:440 - Peak:550 | Yellow
CCB506N14 | 1/2" | Norm:440 - Peak:550 | Black
CCB506N14W | 1/2" | Norm:440 - Peak:550 | Black
CCB516N02W | 1/2" | Norm:440 - Peak:550 | Red
CCB516N09W | 1/2" | Norm:440 - Peak:550 | Blue
CCB516N13W | 1/2" | Norm:440 - Peak:550 | Grey
CCB516N14W | 1/2" | Norm:440 - Peak:550 | Black

www.vte.nl I Power Bushings

TERMINAL INSULATORS METRIC RANGE TERMINAL BUSBARS FUSE HOLDERS POWER POSTS POWER BUSHINGS

## 36

### POWER BUSHINGS (IMPERIAL)

Copper Core Flange Bushing

Part Number | Post | Amperages | Colour
---|---|---|---
CCFB376N02 | 3/8" | Norm:440 - Peak:550 | Red
CCFB376N02W | 3/8" | Norm:440 - Peak:550 | Red
CCFB376N05 | 3/8" | Norm:440 - Peak:550 | Yellow
CCFB376N05W | 3/8" | Norm:440 - Peak:550 | Yellow
CCFB376N14 | 3/8" | Norm:440 - Peak:550 | Black
CCFB376N14W | 3/8" | Norm:440 - Peak:550 | Black
CCFB378N02 | 3/8" | Norm:600 - Peak:750 | Red
CCFB378N02W | 3/8" | Norm:600 - Peak:750 | Red
CCFB378N05 | 3/8" | Norm:600 - Peak:750 | Yellow
CCFB378N05W | 3/8" | Norm:600 - Peak:750 | Yellow
CCFB378N14 | 3/8" | Norm:600 - Peak:750 | Black
CCFB378N14W | 3/8" | Norm:600 - Peak:750 | Black
CCFB506N02 | 1/2" | Norm:440 - Peak:550 | Red
CCFB506N02W | 1/2" | Norm:440 - Peak:550 | Red
CCFB506N05 | 1/2" | Norm:440 - Peak:550 | Yellow
CCFB506N05W | 1/2" | Norm:440 - Peak:550 | Yellow
CCFB506N14 | 1/2" | Norm:440 - Peak:550 | Black
CCFB506N14W | 1/2" | Norm:440 - Peak:550 | Black

Mounts with Bolts or Screws

High energy transfer and High torque capabilities  
High Anti-Rotation  
Maximum Panel Thickness: 9.53mm  
Maximum Voltage: 48 VDC  
Bushing Material: Glass-Filled Nylon  
Fastener (Nut) Material: Stainless Steel  
Post Material: Nickel-Plated Steel  
Weatherproof part (“W”) includes:  
(1)x reinforced silicone gasket & (1)x 232N3 Series insulator

TERMINAL INSULATORS METRIC RANGE TERMINAL BUSBARS FUSE HOLDERS POWER POSTS POWER BUSHINGS

www.vte.nl I Power Bushings

## 37

### POWER BUSHINGS (IMPERIAL)

An effective solution to jumpstarting devices and for providing remote charging capabilities. The copper core is cold swaged into a hex shape equipping high energy transfer performance.

All Jumper Bushings are compatible with common ‘Double D’ punches to increase anti-rotation characteristics.

#### Copper Core Jumper Bushing
Part Number | Post | Amps | Max Voltage | Colour
---|---|---|---|---
CCJB376N0NR02 | 3/8" | 350 | 48 VDC | Red
CCJB376N0N14 | 3/8" | 350 | 48 VDC | Black

High energy transfer and High torque capabilities  
High Anti-Rotation  
Maximum Panel Thickness: 9.53mm  
Maximum Voltage: 48 VDC  
Pass electrical current through a barrier or panel

Bushing Material: Glass-Filled Nylon  
Post Material: Nickel Plated Mild Steel  
Hex Cap Material: Brass  
Includes post insulator, which helps comply with safety regulations

Copper Core Jumper - Flush Mount Kit
Part Number | Post | Amps | Max Voltage | Colour
---|---|---|---|---
CCJB376FMK | 3/8" | 350 | 48 VDC | Red & Black

1x Red Copper Core Jumper Bushing  
1x Black Copper Core Jumper Bushing  
1x Adhesive Decal for installation drilling guide  
1x Protection Divider with Screws (2)  
MOUNT KIT INCLUDED

Copper Core Jumper - Bracket Mount Kit  
Part Number | Post | Amps | Max Voltage | Colour
---|---|---|---|---
CCJB376BMK | 3/8" | 350 | 48 VDC | Red & Black

1x Red Copper Core Jumper Bushing  
1x Black Copper Core Jumper Bushing  
1x Protection Divider with Screws (2)  
1x Mounting Bracket - Powder Coated & Pre-drilled  
MOUNT KIT INCLUDED

www.vte.nl I Power Bushings

## 38

### ELECTRO-MECHANICAL TERMINAL BUSBARS (METRIC)
Whether you need to connect a few high amperage cables, or many low amperage connections in a fast-paced production environment, VTE has a device to fit your application. Ranging from 3 up to 30 connection points, and capable of handling up to 750 amps, you're sure to find a solution to fit your needs.

Our Large 4 Point Terminal Busbar allows for multiple connections to positive and negative systems. Each connection post can maintain multiple connections, making them flexible and robust.

(Images shown)

European Headquarters  
VTE EUROPE BV  
Trapgans 8J Ankeveen 1244RL THE NETHERLANDS  
P: + 31 (0)35-656 5560  
E: info@vte.nl W: www.vte.nl

Oceanic Headquarters  
VTE AUSTRALIA Pty Ltd  
Unit 3/15 Parramatta Road, Underwood QLD 4119  
PO Box 1301, Slacks Creek QLD AUSTRALIA 4127  
P: +61 (0)7 3808 8115  
E: sales@vteaustralia.com W: www.vteauastralia.com

USA Factory / Headquarters  
VTE Inc.  
5437 Robinson Road, Pellston Mi 49769 UNITED STATES  
P: 1 . 231 . 539 . 8000 F: 1 . 231 . 344 . 5914  
E: info@vteworld.com W: www.vteworld.com

www.vte.nl I

## 39

### J2120 (2009 EDITION)
Underwriters Laboratories

VTE-NL_CAT_V2025_D

USA FACTORY / HEADQUARTERS  
VTE Inc.  
5437 Robinson Road, Pellston Mi 49769 UNITED STATES  
P: 1 . 231 . 539 . 8000 F: 1 . 231 . 344 . 5914  
E: info@vteworld.com W: www.vteworld.com

OCEANIC HEADQUARTERS  
®  
VTE AUSTRALIA Pty Ltd  
Unit 3/15 Parramatta Road, Underwood QLD AUSTRALIA 4119  
PO Box 1301, Slacks Creek QLD AUSTRALIA 4127  
P: +61 (0)7 3808 8115  
E: sales@vteaustralia.com W: www.vteaustralia.com

EUROPEAN HEADQUARTERS  
VTE EUROPE BV  
Trapgans 8J Ankeveen 1244RL THE NETHERLANDS  
P: + 31 (0)35-656 5560  
E: info@vte.nl W: www.vte.nl

## 40

(End page with catalog footer/address and graphics; readable text not present beyond what already appears on page 39 in the provided images.)