The high-voltage DC relay EVC-serie adopts a ceramic sealing structure, which can cut off the load voltage of up to 1000VDC. The high-voltage DC relay EVC-serie can maintain stable contact resistance regardless of the environment.
With ceramic seal structure, the contact chamber filled with hydrogen mixed reducing gas, combined with magnetic blow-out.
Voltage relay can cut off load voltage of 1000VDC.
Compact Design & Low Operating Sound
By using a capsule contact mechanism that is enclosed with hydrogen gas, highcapacity cutoff is possible even with a tiny contact gap. There is little operating sound, which does not change even when large currents are cut off.
The enclosure box is smaller thanks to an arc-space-free construction from which the arc will not get out. Arc will not get out with design of that contacts are enclosed in a sealed capsule.
The contact part is hermetically sealed with H2 mixed gas, hence the contact resistance remains stable regardless of the ambient conditions.
| Characteristics | EVC1000 | EVC600 | EVC400 | EVC350 | EVC250 | EVC150 | EVC100 | EVC050 |
| Mechanical life | 2×105 Ops | 2×105 Ops | 2×105 Ops | 2×105 Ops | 2×105 Ops | 2×105 Ops | 2×105 Ops | 2×105 Ops; |
| Electrical life | 450V DC 350A 3 000Ops , 750V DC 350A 1000 Ops , 450V DC 1000A 100Ops | 450V DC 350A 3000Ops , 750V DC 350A 1000 Ops | 450V/I△ 3000Ops , 750V/△ 500 Ops | 450V/I△ 3000Ops , 750V/△ 1000 Ops | 450V/I△ 6000Ops , 750V/△ 1000 Ops | 450V/I△ 6000Ops ,750V/△ 1000 Ops | 450V/I△ 6000Ops , 750V/△ 1000 Ops | 450V/I△ 6000Ops , 750V/△ 1000 Ops |
| Ambient temperature | -40℃ to +85℃ | -40℃ to +85℃ | -40℃ to +85℃ | -40℃ to +85℃ | -40℃ to +85℃ | -40℃ to +85℃ | -40℃ to +85℃ | -40℃ to +85℃ |
| Humidity | 5% to 8 5 % R.H. | 5% to 85 % R.H. | 5% to 95 % R.H. | 5% to 95 % R.H. | 5% to 95 % R.H. | 5% to 95 % R.H. | 5% to 95 % R.H. | 5% to 95 % R.H. |
| Weight | 110 0g | 900g | 550g | 550g | 380g | 380g | 180g | 180g |
| insulation resistance | Min.100MΩ 500V DC | Min.100MΩ 500V DC | Min.100MΩ 500V DC | |||||
| Contact resistance | ≤0.5mΩ(DC 300A) | ≤0.5mΩ(DC250A) | ≤0.5mΩ(DC150A) | ≤1.5mΩ(DC 50A) | ||||
| Between open contacts | 25 00V AC 60Sec.10mA | 2500V AC 60Sec.10mA | 3000V AC 60Sec.10mA | 2500V AC 60Sec.10mA | 2500V AC 60Sec.10mA | 2500V AC 60Sec.10mA | 2500V AC 60Sec.10mA | 2500V AC 60Sec.10mA |
| Between contact and coil | 25 00V AC 60 Sec.10mA | 2500V AC 60 Sec.10mA | 3000V AC 60 Sec.10mA | 3000V AC 60 Sec.10mA | 3000V AC 60 Sec.10mA | 3000V AC 60 Sec.10mA | 3000V AC 60 Sec.10mA | 3000V AC 60 Sec.10mA |
| Air gap | 6mm | 6mm | ||||||
| Creepage interval | 10mm | 10mm | ||||||
| Surge resistant voltage | 5000V AC | 5000V AC | ||||||
| Coil voltage | 9~36 DC | 9~36 DC | 9~36V DC | 9~36V DC | 9~36V DC | 12V DC/24V/V DC | ||
| Coil power | when switched on 45.6W(0.12s) when held:3.4W | when switched on45.6W(0.12s) when held:3.4W | when switched on43.2W(0.12s) when held:1.7W | 5.5W | ||||
| Holding current | 0.54A@12VDC 0.24A@24VDC | 0.27A@12VDC 0.12A@24VDC | ||||||
| Pull-in voltage | ≤9VDC | ≤9VDC | ||||||
| Release voltage | ≥5VDC | ≥5VDC | ||||||
| Energy saving mode | PWM | |||||||
| Short time power | 450A 600min 1200A 30s 600A 20min 3000A 0.6s | 320A 10min 500A 1min 2000A 1s | 200A 10min 300A 1min 1000A 1s | 80A 600s 120A 60s 500A 1s | ||||
| Operating temperature | -40℃~85℃ | -40℃~85℃ | 40 ° C ~ 85 ° C | -40℃~85℃ | -40℃~85℃ | -40℃~85℃ | -40℃~85℃ | -40℃~85℃ |